Daktronics C44 Manual do Utilizador Página 50

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 49
4-2 Maintenance &
Troubleshooting
Tree Problems
Symptom/Condition Possible Cause/Remedy
Tree does not light at all Check power and fuse to tree
Check power to isolation interface
Check bottom left corner of screen for SLCK
If SLCK is there, check power to starter’s box
interface
Check SBI to see if 3 LED’s are lit, Trans and Rec
leads from SBI to isolation interface may be
switched
Check SBI Trans and Rec LED’s on isolation
interface
Check communications cable which transmits data
from C-44 to SLEB
Bulb in tree not lit Change bulb
Check socket and wiring
Change driver board
Bulb in tree stays lit Change driver board
Tree Flickers Check Grounding wires in Start line Box
Printer Problems
Symptom/Condition Possible cause/remedy
Printer not working Check to see if printer is enabled at C-44
Check power and connectors
Check to see if printer select light is lit
If Log printer Check communications cable which sends data to
log printer
If E.T. printer Check time slip printer interface LED’s
Check E.T. printer data LED on isolation interface
Check E.T. printer fault LED on isolation interface
Check communications cable which sends data to
E.T. printer
Display Problems
Symptom/Condition Possible Cause/Remedy
No display at scoreboards Enabled in C-44 Configuration Menu?
Check power to isolation interface and displays
Check display transmitter board In C-44,
(Drawing A-55998) which sends data to displays
via isolation interface.
Check for + 12VDC on signal input of driver.
Dial-ins not showing In the scoreboard enable mode, was a Y placed in
the dial-in?
Is the F5 key being depressed?
Vista de página 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 80 81